MCQs: Dilatometer is used to measure __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Relationship between absorption/evolution of heat at the thermocouple junctions and the current flow in the circuit is given by _____________ effect?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: pH meter has ____________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Flow rate of those fluids which are insensitive to changes in their density, viscosity or flow velocity profile can be best measured by a ________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Working principle of mercury in glass thermometer is based on volumetric expansion of mercury with increase in temperature. Which of the following undergoes minimum volumetric expansion for a given temperature change ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Which of the following filled system expansion thermometer has the capability to measure the lowest temperature ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Emf generated in a thermocouple depends on the temperature ___________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Which of the following thermocouples can measure the maximum temperature ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Optical activity of a solution can be determined using a ___________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Strain gage uses an electrical conductor wire, which when elastically stretched increases in length and reduces in diameter. Both these dimensional changes result in ____________ in the electrical resistance of the wire ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Which of the following is not a composition measuring instrument ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Response of a linear control system for a change in set point is called __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Stroboscope is used for the measurement of _________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Nickel percentage in invar which is an iron-nickel alloy, and is used as a thermocouple material is __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Conversion formula for converting amplitude ratio (AR) into decibels is ________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Liquid flow rate in an open channel cannot be measured by a/an __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Temperature of molten pig iron (1450°C) and molten slag (1500°C) flowing out of a blast furnace is measured by a/an_______________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Which of the following is never used as an element of industrial resistance thermometer ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Emf developed by a thermocouple while measuring a temperature of 800°C is about 31 mV. The type of thermocouple used is________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Hot wire anemometer is used for the measurement of___________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|