Design of Steel Structures Mcqs

Q.  The difference between gross diameter and nominal diameter for the rivets up to 25 mm diameter is__________________?

a. 1.0 mm
b. 1.5 mm
c. 2.0 mm
d. 2.5 mm


ANSWER: See Answer
 
No explanation is available for this question!
MCQs:  A circular column section is generally not used in actual practice because________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The best arrangement to provide unified behaviour in built up steel columns is by______________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The use of tie plates in laced columns is_________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Angle of inclination of the lacing bar with the longitudinal axis of the column should preferably be between____________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The effective length of a battened column is increased by_________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The slenderness ratio of lacing bars should not exceed________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Shear buckling of web in a plate girder is prevented by using________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Minimum thickness of web in a plate girder, when the plate is accessible and also exposed to weather, is______________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  As per IS : 800, for compression flange, the outstand of flange plates should not exceed________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Bearing stiffener in a plate girder is used to__________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Gantry girders are designed to resist_________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Rivets connecting flange angles to cover plates in a plate girder are subjected to_________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The range of economical spacing of trusses varies from________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Normally, the angle of roof truss with asbestos sheets should not be less than_______________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Generally the purlins are placed at the panel points so as to avoid__________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The relation between intensity of wind pressure p and velocity of wind V is taken as_______________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The internal pressure coefficient on walls for buildings with large permeability is taken as_______________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The risk coefficient k, depends on__________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  Area of openings for buildings of large permeability is more than_________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts
MCQs:  The number of seismic zones in which the country has been divided are_________________?
Category: Civil Engineering Mcqs,   Published by: T-Code Scripts