Q.  Temperature control of an exothermic chemical reaction taking place in a CSTR is done with the help of cooling water flowing in a jacket around the reactor. The types of valve and controller action to be recommended are________________?

a. Air to open valve with the controller direct acting
b. Air to close valve with the controller indirect acting
c. Air to open valve with the controller indirect acting
d. Air to close valve with the controller direct acting


ANSWER: See Answer
 
No explanation is available for this question!
MCQs:  Bourdon gauges are used for measuring pressure (kg/cm2) ?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Thermodynamic Celsius scale of temperature measurement is________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Routh test_________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  A stable system is the one___________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Mercury thermometer is commonly used for low temperature measurement. The freezing point and boiling point of mercury are respectively _____________ °C?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Compositional analysis of flue gas coming out of a furnace in respect of O2 and CO2% can be continuously done by a/an___________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  A manometer measures the _____________ pressure?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Bimetal strips are not used in________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  In second order underdamped system ?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Non-metallic diaphragm used as pressure sensor in instruments is generally made of__________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Reference points i.e., ice point and steam point in Reaumer temperature scale are respectively_________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Which of the following thermocouples is capable of measuring a temperature of -50°C ?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  For two non-interacting first order systems connected in series, the overall transfer function is the ______________ of the individual transfer functions?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  If response of a control system is to be free of offset and oscillation, the most suitable controller is_________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Which of the following is not classified as a thermo electric pyrometer ?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Continuous measurement of specific gravity of a liquid is done by __________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  In a shell and tube heat exchanger, the outlet temperature of heating/cooling fluid is the _____________ variable?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Flame photometry is used for the determination of compositional analysis of_______________?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Photoelectric pyrometers are suitable in the temperature range of ________________ °C?
Category: Chemical Engineering Mcqs,   Published by: teswesm
MCQs:  Composition of natural gas is determined by the_________________?
Category: Chemical Engineering Mcqs,   Published by: teswesm