MCQs: Which of the following is not a composition measuring instrument ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Response of a linear control system for a change in set point is called __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Stroboscope is used for the measurement of _________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Nickel percentage in invar which is an iron-nickel alloy, and is used as a thermocouple material is __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Conversion formula for converting amplitude ratio (AR) into decibels is ________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Liquid flow rate in an open channel cannot be measured by a/an __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Temperature of molten pig iron (1450°C) and molten slag (1500°C) flowing out of a blast furnace is measured by a/an_______________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Which of the following is never used as an element of industrial resistance thermometer ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Emf developed by a thermocouple while measuring a temperature of 800°C is about 31 mV. The type of thermocouple used is________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Hot wire anemometer is used for the measurement of___________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Phase lag of the sinusoidal response of a first order system is _________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: When the damping co-efficient (ξ) is unity, the system is __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: A system with transfer function [(2S/4S) + 1] is of _____________ order?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Flow rate measurement of hostile acids and alkalis can be most suitably done by a/an ________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Platinum resistance thermometer is the international standard for temperature measurement between __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Which of the following thermocouple materials does not contain nickel ?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: To increase the speed of response of a pressure spring liquid or gas expansion thermometer, the clearance space between the thermometer bulb and the thermal well should not be filled with ________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Specific gravity of a liquid cannot be measured by a/an __________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: Mass spectrometer is used for the composition analysis of____________________?
Category: Chemical Engineering Mcqs, Published by: teswesm
|
MCQs: The ______________ of a vapor pressure thermometer is a primary element?
Category: Chemical Engineering Mcqs, Published by: teswesm
|